{"title":"Connectors","description":null,"products":[{"product_id":"rj45-socket","title":"NEXUS CAT6A RJ45 Connectors 100 Pack Pass-Through 10Gbps Ethernet Plug","description":"\u003cp\u003eProfessional-grade \u003cstrong data-start=\"607\" data-end=\"632\"\u003eCAT6A RJ45 connectors\u003c\/strong\u003e designed for \u003cstrong data-start=\"646\" data-end=\"676\"\u003e10Gbps high-speed networks\u003c\/strong\u003e, supporting both \u003cstrong data-start=\"694\" data-end=\"714\"\u003eUTP (Unshielded)\u003c\/strong\u003e and \u003cstrong data-start=\"719\" data-end=\"738\"\u003eSFTP (Shielded)\u003c\/strong\u003e cables. Built for installers who want \u003cstrong data-start=\"777\" data-end=\"839\"\u003ereliability, clean termination, and zero signal compromise\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-section-id=\"6etktn\" data-start=\"1152\" data-end=\"1169\"\u003e🚀 KEY FEATURES\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1ggsoe\" data-start=\"1171\" data-end=\"1208\"\u003e⚡ 10Gbps Performance (True CAT6A)\u003c\/h3\u003e\n\u003cul data-start=\"1209\" data-end=\"1329\"\u003e\n\u003cli data-section-id=\"ubfm19\" data-start=\"1209\" data-end=\"1249\"\u003eSupports up to \u003cstrong data-start=\"1226\" data-end=\"1249\"\u003e10 Gigabit Ethernet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4al5js\" data-start=\"1250\" data-end=\"1279\"\u003eFrequency up to \u003cstrong data-start=\"1268\" data-end=\"1279\"\u003e500 MHz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w0pdww\" data-start=\"1280\" data-end=\"1329\"\u003eStable transmission for \u003cstrong data-start=\"1306\" data-end=\"1329\"\u003eenterprise networks\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1331\" data-end=\"1334\"\u003e\n\u003ch3 data-section-id=\"175yq1o\" data-start=\"1336\" data-end=\"1361\"\u003e🧲 UTP \u0026amp; SFTP OPTIONS\u003c\/h3\u003e\n\u003cul data-start=\"1362\" data-end=\"1485\"\u003e\n\u003cli data-section-id=\"c9s6zb\" data-start=\"1362\" data-end=\"1404\"\u003e\n\u003cstrong data-start=\"1364\" data-end=\"1371\"\u003eUTP\u003c\/strong\u003e → For standard indoor networks\u003c\/li\u003e\n\u003cli data-section-id=\"1swl4dh\" data-start=\"1405\" data-end=\"1485\"\u003e\n\u003cstrong data-start=\"1407\" data-end=\"1426\"\u003eSFTP (Shielded)\u003c\/strong\u003e → For \u003cstrong data-start=\"1433\" data-end=\"1458\"\u003ehigh EMI environments\u003c\/strong\u003e (industrial, server rooms)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1487\" data-end=\"1490\"\u003e\n\u003ch3 data-section-id=\"7gacew\" data-start=\"1492\" data-end=\"1540\"\u003e🧩 Pass-Through Design (Installer Advantage)\u003c\/h3\u003e\n\u003cul data-start=\"1541\" data-end=\"1603\"\u003e\n\u003cli data-section-id=\"72v5ne\" data-start=\"1541\" data-end=\"1558\"\u003eFaster crimping\u003c\/li\u003e\n\u003cli data-section-id=\"4f48lm\" data-start=\"1559\" data-end=\"1582\"\u003eVisual wire alignment\u003c\/li\u003e\n\u003cli data-section-id=\"mni106\" data-start=\"1583\" data-end=\"1603\"\u003eReduced error rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1605\" data-end=\"1608\"\u003e\n\u003ch3 data-section-id=\"8hkb70\" data-start=\"1610\" data-end=\"1637\"\u003e🟡 Gold-Plated Contacts\u003c\/h3\u003e\n\u003cul data-start=\"1638\" data-end=\"1703\"\u003e\n\u003cli data-section-id=\"gqm6c9\" data-start=\"1638\" data-end=\"1657\"\u003eHigh conductivity\u003c\/li\u003e\n\u003cli data-section-id=\"7o0ii7\" data-start=\"1658\" data-end=\"1674\"\u003eAnti-corrosion\u003c\/li\u003e\n\u003cli data-section-id=\"1gbmyje\" data-start=\"1675\" data-end=\"1703\"\u003eLong-term signal stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1705\" data-end=\"1708\"\u003e\n\u003ch3 data-section-id=\"17tfnyc\" data-start=\"1710\" data-end=\"1741\"\u003e🔧 Wide Cable Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"1742\" data-end=\"1856\"\u003e\n\u003cli data-section-id=\"15r93gp\" data-start=\"1742\" data-end=\"1790\"\u003eSupports \u003cstrong data-start=\"1753\" data-end=\"1790\"\u003e23AWG \u0026amp; 24AWG solid copper cables\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"hz1i3w\" data-start=\"1791\" data-end=\"1856\"\u003eIdeal for:\n\u003cul data-start=\"1806\" data-end=\"1856\"\u003e\n\u003cli data-section-id=\"hkt9gj\" data-start=\"1806\" data-end=\"1825\"\u003eCAT6A bulk cables\u003c\/li\u003e\n\u003cli data-section-id=\"16wal9f\" data-start=\"1828\" data-end=\"1856\"\u003eStructured cabling systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1858\" data-end=\"1861\"\u003e\n\u003ch3 data-section-id=\"masemm\" data-start=\"1863\" data-end=\"1898\"\u003e🛡️ Secure Locking \u0026amp; Durability\u003c\/h3\u003e\n\u003cul data-start=\"1899\" data-end=\"1963\"\u003e\n\u003cli data-section-id=\"hqlxi1\" data-start=\"1899\" data-end=\"1922\"\u003eStrong clip retention\u003c\/li\u003e\n\u003cli data-section-id=\"15zfqwg\" data-start=\"1923\" data-end=\"1940\"\u003eHigh cycle life\u003c\/li\u003e\n\u003cli data-section-id=\"2680vq\" data-start=\"1941\" data-end=\"1963\"\u003eNo loose connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1o2l2cm\" data-start=\"1653\" data-end=\"1692\"\u003e🧩 100 PCS JAR PACK \u003c\/h3\u003e\n\u003cul data-start=\"1693\" data-end=\"1781\"\u003e\n\u003cli data-section-id=\"1pnk3w6\" data-start=\"1693\" data-end=\"1720\"\u003eEasy storage \u0026amp; handling\u003c\/li\u003e\n\u003cli data-section-id=\"1peyqbh\" data-start=\"1721\" data-end=\"1743\"\u003eNo lost connectors\u003c\/li\u003e\n\u003cli data-section-id=\"1nqx9vp\" data-start=\"1744\" data-end=\"1781\"\u003ePerfect for installers \u0026amp; projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eCAT6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eRJ45 8P8C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Compatibility\u003c\/td\u003e\n\u003ctd\u003e23AWG \/ 24AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eUTP \/ SFTP (Shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 10Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eUp to 500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Material\u003c\/td\u003e\n\u003ctd\u003ePhosphor Bronze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Plating\u003c\/td\u003e\n\u003ctd\u003eGold-Plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (UTP) \/ Metal Shield (SFTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003ePass-Through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Compliance\u003c\/td\u003e\n\u003ctd\u003eTIA\/EIA-568\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLAN \/ Data Centers \/ CCTV \/ Smart Systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch1 data-section-id=\"153gonx\" data-start=\"3329\" data-end=\"3347\"\u003e🛠️ APPLICATIONS\u003c\/h1\u003e\n\u003cul data-start=\"3349\" data-end=\"3477\"\u003e\n\u003cli data-section-id=\"1fb6p2b\" data-start=\"3349\" data-end=\"3379\"\u003eStructured Cabling Systems\u003c\/li\u003e\n\u003cli data-section-id=\"1ml6mdc\" data-start=\"3380\" data-end=\"3396\"\u003eData Centers\u003c\/li\u003e\n\u003cli data-section-id=\"m3epd1\" data-start=\"3397\" data-end=\"3419\"\u003eCCTV Installations\u003c\/li\u003e\n\u003cli data-section-id=\"17pd26m\" data-start=\"3420\" data-end=\"3442\"\u003eSmart IoT Networks\u003c\/li\u003e\n\u003cli data-section-id=\"aeh3l8\" data-start=\"3443\" data-end=\"3477\"\u003eOffice \u0026amp; Commercial Networking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-section-id=\"1100q62\" data-start=\"3484\" data-end=\"3539\"\u003e🎯 WHY NEXUS \u003c\/h1\u003e\n\u003cul data-start=\"3541\" data-end=\"3720\"\u003e\n\u003cli data-section-id=\"174xar9\" data-start=\"3541\" data-end=\"3586\"\u003e✔️ Designed for \u003cstrong data-start=\"3559\" data-end=\"3586\"\u003eprofessional installers\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dpmu0p\" data-start=\"3587\" data-end=\"3630\"\u003e✔️ Compatible with \u003cstrong data-start=\"3608\" data-end=\"3630\"\u003eNEXUS CAT6A cables\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"72uxv7\" data-start=\"3631\" data-end=\"3671\"\u003e✔️ Tested for \u003cstrong data-start=\"3647\" data-end=\"3671\"\u003ereliable termination\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1v8gmae\" data-start=\"3672\" data-end=\"3720\"\u003e✔️ Built for \u003cstrong data-start=\"3687\" data-end=\"3720\"\u003ereal project environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Nexus","offers":[{"title":"NEXUS CAT6A UTP RJ45 100Pack Socket","offer_id":44753481498821,"sku":"rj45-cat6a-100pack","price":54.0,"currency_code":"AED","in_stock":true},{"title":"NEXUS CAT6A FTP RJ45 100Pack Socket","offer_id":44753481531589,"sku":"rj45-cat6a-ftp","price":74.0,"currency_code":"AED","in_stock":true},{"title":"AMP Socket 50Pack","offer_id":43641369624773,"sku":"","price":35.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/ftp.jpg?v=1775734747"},{"product_id":"nexus-cat6a-keystone","title":"NEXUS CAT6A \u0026 CAT7  Keystone Jack (5-Pack + Zip Ties)","description":"\u003ch3 data-end=\"851\" data-start=\"826\"\u003e💡 \u003cstrong data-end=\"851\" data-start=\"833\"\u003eKey Highlights\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1226\" data-start=\"852\"\u003e⚡ 10 Gbps Data Transmission – High-speed CAT6A\/CAT7 performance up to 500 MHz\u003cbr data-end=\"932\" data-start=\"929\"\u003e🔧 Tool-Free Ratchet Lock – No punch-down tool needed\u003cbr data-end=\"988\" data-start=\"985\"\u003e🛡️ 8-Pin Gold-Plated Contacts – Excellent signal integrity\u003cbr data-end=\"1050\" data-start=\"1047\"\u003e🧰 Reusable Housing – Perfect for structured cabling\u003cbr data-end=\"1105\" data-start=\"1102\"\u003e📦 5-Pack with 5 Zip Ties – Neat and professional installation\u003cbr data-end=\"1170\" data-start=\"1167\"\u003e🏗️ Flame-Retardant ABS – Strong and safe construction\u003c\/p\u003e\n\u003ch3 data-end=\"1830\" data-start=\"1808\"\u003e\u003cstrong data-end=\"1830\" data-start=\"1815\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2192\" data-start=\"1832\"\u003eThe \u003cstrong data-end=\"1876\" data-start=\"1836\"\u003eNEXUS CAT6A \u0026amp; CAT7 UTP and SFTP Keystone Jack\u003c\/strong\u003e delivers professional-grade \u003cstrong data-end=\"1921\" data-start=\"1905\"\u003e10Gbps speed\u003c\/strong\u003e and a \u003cstrong data-end=\"1948\" data-start=\"1928\"\u003etool-free design\u003c\/strong\u003e for effortless installation.\u003cbr data-end=\"1980\" data-start=\"1977\"\u003eWith \u003cstrong data-end=\"2007\" data-start=\"1985\"\u003e8 gold-plated pins\u003c\/strong\u003e ensuring strong signal integrity and a \u003cstrong data-end=\"2068\" data-start=\"2047\"\u003edurable ABS shell (UTP)\u003c\/strong\u003e, \u003cstrong\u003eSteel Metal (SFTP)\u003c\/strong\u003e it’s perfect for \u003cstrong data-end=\"2131\" data-start=\"2087\"\u003ehome networks, offices, and data centers\u003c\/strong\u003e.\u003cbr data-end=\"2135\" data-start=\"2132\"\u003eIncludes \u003cstrong data-end=\"2158\" data-start=\"2144\"\u003e5 zip ties\u003c\/strong\u003e for a tidy and organized setup.\u003c\/p\u003e\n\u003cp data-end=\"2343\" data-start=\"2194\"\u003e✅ Ideal for wall plates, patch panels, and faceplates.\u003cbr data-end=\"2251\" data-start=\"2248\"\u003e✅ Universal compatibility with CAT5e–CAT7 cables.\u003cbr data-end=\"2303\" data-start=\"2300\"\u003e✅ Built to last with zero maintenance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEXUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT6A \u0026amp; CAT7 UTP Keystone Jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUTP (Unshielded Twisted Pair) - SFTP ( Shielded )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (8P8C Gold-Plated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTool-Free Ratchet Lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame-Retardant ABS - Shielded Metal Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Keystone Jacks + 5 Zip Ties\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT6A, CAT7, CAT6, CAT5e cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack \u0026amp; White - Silver \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Nexus","offers":[{"title":"UTP","offer_id":45160651325637,"sku":"Keystone5pack-UTP","price":49.0,"currency_code":"AED","in_stock":true},{"title":"SFTP","offer_id":45160651358405,"sku":"Keystone5pack-SFTP","price":72.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/001.jpg?v=1760022377"},{"product_id":"cat7-cat6a-tool-less-rj45","title":"CAT7 \u0026 CAT6A Tool-Less RJ45 Connector Full Metal Shielded","description":"\u003ch2\u003eCAT7 Tool-Less RJ45 Connector | Full Metal Shielded | 22 - 26 AWG\u003c\/h2\u003e\n\u003cp\u003eProfessional-grade \u003cstrong\u003eCAT7 tool-less RJ45 connector\u003c\/strong\u003e with \u003cstrong\u003efull metal shielding\u003c\/strong\u003e, designed for fast installation and reliable \u003cstrong\u003e10Gbps Ethernet performance\u003c\/strong\u003e.\u003cbr\u003eSupports \u003cstrong\u003e22AWG - 26AWG CAT7 SFTP \/ UTP cables\u003c\/strong\u003e—ideal for installers, data centers, and structured cabling projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🔧 Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Metal Shielded Housing\u003c\/strong\u003e\u003cbr\u003eSteel body provides proper grounding and strong EMI\/RFI protection for stable, noise-free data transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-Less \u0026amp; Reusable Design\u003c\/strong\u003e\u003cbr\u003eNo crimping tools required. Enables fast field termination and easy re-termination during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupports 22 - 26 AWG Conductors\u003c\/strong\u003e\u003cbr\u003eEngineered for CAT7 SFTP \u0026amp; UTP cables using \u003cstrong\u003e22AWG - 26AWG solid copper conductors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10Gbps High-Speed Performance\u003c\/strong\u003e\u003cbr\u003eOptimized for high-bandwidth networks, enterprise environments, and professional installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Installation Grade\u003c\/strong\u003e\u003cbr\u003eIdeal for network engineers, CCTV installers, system integrators, and industrial networking projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e⚙️ Product Overview\u003c\/h2\u003e\n\u003cp\u003eThis \u003ca href=\"https:\/\/shop.nexustrd.com\/collections\/accessories\/products\/cat7-cat6a-tool-less-rj45\"\u003e\u003cstrong\u003eCAT7 Tool-Less RJ45 Connector\u003c\/strong\u003e\u003c\/a\u003e is built for modern Ethernet installations where speed, shielding, and reliability are critical.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003efull metal shielded construction\u003c\/strong\u003e ensures effective grounding and minimizes electromagnetic interference, delivering consistent \u003cstrong\u003e10Gbps network performance\u003c\/strong\u003e even in demanding environments.\u003c\/p\u003e\n\u003cp\u003eWith its \u003cstrong\u003etool-free termination design\u003c\/strong\u003e, installation is faster and cleaner compared to traditional crimped connectors—reducing errors and saving valuable installation time.\u003c\/p\u003e\n\u003cp\u003eCompatible with \u003cstrong\u003eCAT7 SFTP \u0026amp; UTP cables\u003c\/strong\u003e using \u003cstrong\u003e22AWG - 26AWG solid conductors\u003c\/strong\u003e, this connector is a reliable solution for professional structured cabling systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e🧪 Technical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e RJ45 (8P8C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCategory Support:\u003c\/strong\u003e CAT7 CAT6A CAT6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Types:\u003c\/strong\u003e SFTP \/ UTP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Size:\u003c\/strong\u003e 22AWG - 26AWG \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Full Metal Zinc Alloy \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e Yes (EMI\/RFI Protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e Tool-Less, Reusable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Rate:\u003c\/strong\u003e Up to 10Gbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Ethernet \/ LAN \/ Structured Cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e🏗️ Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eData centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffice structured cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCCTV \u0026amp; IP camera installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial and commercial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork upgrades and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e📊 Comparison – Why Choose This Connector?\u003c\/h2\u003e\n\u003ctable style=\"width: 100.087%; height: 137.157px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 24.2173%; height: 19.5938px;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"width: 39.6177%; height: 19.5938px;\"\u003eCAT7 Tool-Less Metal RJ45\u003c\/th\u003e\n\u003cth style=\"width: 32.2655%; height: 19.5938px;\"\u003eStandard Plastic RJ45\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003eFull Metal Shielded\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eEMI Protection\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003eHigh\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003eLow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eTool Required\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eReusable\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eAWG Support\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003e22 -26 AWG\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003eLimited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 24.2173%; height: 19.5938px;\"\u003eInstallation Speed\u003c\/td\u003e\n\u003ctd style=\"width: 39.6177%; height: 19.5938px;\"\u003eFast\u003c\/td\u003e\n\u003ctd style=\"width: 32.2655%; height: 19.5938px;\"\u003eSlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e✅ Why Professionals Choose This Connector\u003c\/h2\u003e\n\u003cp\u003e✔ Faster installation\u003cbr\u003e✔ Stronger signal integrity\u003cbr\u003e✔ Better grounding \u0026amp; shielding\u003cbr\u003e✔ Reusable for maintenance work\u003cbr\u003e✔ Built for professional CAT7 networks\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nexus","offers":[{"title":"2-Pack","offer_id":45612738150597,"sku":"CAT7-RJ45-2pack-1","price":25.0,"currency_code":"AED","in_stock":true},{"title":"4-Pack","offer_id":45612738183365,"sku":"CAT7-RJ45-4pack-2","price":47.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/1_2.jpg?v=1768037473"},{"product_id":"cat6a-utp-rj45-tool-less-connector-10gbps-ethernet-termination-reusable-network-plug","title":"NEXUS CAT6A UTP RJ45 Tool-less Connector 10Gbps Ethernet Termination Reusable Network Plug","description":"\u003c!-- BADGES --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px; margin-bottom: 20px;\"\u003e\n\u003cspan style=\"background: #FEF0E6; color: #c0510f; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e⚡ 10 Gbps\u003c\/span\u003e \u003cspan style=\"background: #EAF5E9; color: #276221; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🔧 No Tools Required\u003c\/span\u003e \u003cspan style=\"background: #EBF5FB; color: #1a6fa3; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e CAT6A \/ Class EA\u003c\/span\u003e \u003cspan style=\"background: #F4ECF7; color: #6c3483; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🔁 Re-termination Ready\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- TITLE \u0026 INTRO --\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eTerminate CAT6A cable in seconds — \u003cstrong\u003eno crimping tool, no punch-down block, no experience needed.\u003c\/strong\u003e The Nexus CAT6A UTP Tool-less RJ45 Connector uses a built-in IDC (Insulation Displacement Contact) mechanism that locks each conductor in place with a simple push and click. Professional results, every time.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 24px;\"\u003eRated for \u003cstrong\u003e10 Gbps at 500MHz\u003c\/strong\u003e, this connector is fully compliant with CAT6A Class EA specifications and fits all standard RJ45 ports and patch panels. The tool-less design makes it the go-to choice for installers, IT teams, and home networkers who want a clean, reliable termination without carrying a full toolkit.\u003c\/p\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- SPECS TABLE --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666; width: 45%;\"\u003eCategory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCAT6A \/ Class EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e10 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eUTP (Unshielded Twisted Pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eCompatible Cable OD\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e6.0 – 8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eConductor Size\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e22 – 26 AWG solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eTermination Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eTool-less IDC (push \u0026amp; click)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eRe-termination\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eYes — open, re-seat, re-close\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eContact Material\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e50µ Gold-plated contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eWiring Standard\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eT568A \/ T568B compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eHousing Colour\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eWhite \/ Grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eBackwards Compatible\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCAT5e \/ CAT6 \/ CAT6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- HOW IT WORKS --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 10px;\"\u003eHow it works — 4 steps, no tools\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eForget the crimper. The Nexus tool-less connector uses an integrated IDC cap that presses each conductor into its gold contact the moment you close the housing. The built-in cable guide ensures correct pair separation and wiring order before you lock it shut — meaning even first-time installers get a perfect termination.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #FEF0E6;\"\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 13px; font-weight: bold; color: #c0510f; width: 32px; text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 14px; color: #333;\"\u003e\n\u003cstrong\u003eStrip\u003c\/strong\u003e — remove 25–30mm of outer jacket. No need to strip individual conductors.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 13px; font-weight: bold; color: #c0510f; text-align: center;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 14px; color: #333;\"\u003e\n\u003cstrong\u003eSeparate\u003c\/strong\u003e — fan the pairs into the colour-coded cable guide channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #FEF0E6;\"\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 13px; font-weight: bold; color: #c0510f; text-align: center;\"\u003e3\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 14px; color: #333;\"\u003e\n\u003cstrong\u003eInsert\u003c\/strong\u003e — push the cable through the rear of the connector body until conductors are fully seated.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 13px; font-weight: bold; color: #c0510f; text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 14px; font-size: 14px; color: #333;\"\u003e\n\u003cstrong\u003eClick\u003c\/strong\u003e — close the IDC cap. Done. The connector is ready to plug in and test.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- KEY FEATURES --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eKey features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eTruly tool-less\u003c\/strong\u003e — no crimper, no punch-down tool, no krone tool required\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e10 Gbps \/ 500MHz\u003c\/strong\u003e — full CAT6A Class EA performance rating\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eRe-termination capable\u003c\/strong\u003e — open the cap, re-seat conductors, close again — no waste\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e50µ gold-plated contacts\u003c\/strong\u003e — corrosion-resistant for long-term connection reliability\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eColour-coded wiring guide\u003c\/strong\u003e — built into the connector body, supports T568A and T568B\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eFits 22–26 AWG solid and stranded\u003c\/strong\u003e — compatible with all standard UTP cable\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eStandard RJ45 form factor\u003c\/strong\u003e — fits all patch panels, wall plates, and network switches\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eBuilt-in strain relief\u003c\/strong\u003e — cable clamp prevents pull-out and conductor stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- IDEAL FOR --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eIdeal for\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eNetwork installers and IT engineers working on-site without a full toolkit\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eHome and office CAT6A structured cabling installations\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eQuick field repairs and emergency re-terminations\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eData centre patching and cabinet builds\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003ePoE camera and access point runs (supports PoE++)\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eAnyone terminating cable for the first time — no skill or experience needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- TOOL-LESS vs TRADITIONAL CRIMP --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 14px;\"\u003eTool-less vs. traditional crimp connector\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px; font-size: 13px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 10px 14px; text-align: left; font-weight: bold; color: #444;\"\u003e\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; text-align: center; font-weight: bold; color: #c0510f;\"\u003eNexus Tool-less\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; text-align: center; font-weight: bold; color: #666;\"\u003eTraditional Crimp\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eTools needed\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eNone\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #666;\"\u003eCrimping tool required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eRe-termination\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #c0510f;\"\u003eNo — single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eTermination time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003e\u0026lt; 60 seconds\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #666;\"\u003e2–5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eSkill required\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eNone\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #666;\"\u003ePractice needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eCAT6A rated\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eYes — 10Gbps \/ 500MHz\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221;\"\u003eYes (if CAT6A spec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eGold contacts\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003e50µ gold-plated\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #666;\"\u003eVaries by brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- FAQ --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 16px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eDo I really need zero tools?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eYes — just a cable stripper (or a sharp knife) to remove the outer jacket. No crimping tool, no krone\/punch-down tool, and no screwdriver needed. The IDC mechanism does all the work when you close the cap.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWill it work with my existing CAT6 or CAT5e cable?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eYes. These connectors are backwards compatible and will terminate CAT5e, CAT6, and CAT6A UTP cable. For CAT6A performance (10Gbps), ensure you're using a rated CAT6A cable.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eCan I re-use the connector if I make a wiring mistake?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eAbsolutely. Simply open the IDC cap, remove the cable, re-seat the conductors correctly, and close it again. Unlike traditional crimp connectors — which are single-use — this connector can be opened and re-terminated multiple times.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eDoes it support PoE?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eYes. The 50µ gold-plated contacts and secure IDC termination handle PoE and PoE+ (IEEE 802.3at\/bt) loads without issue — ideal for IP cameras, wireless access points, and VoIP handsets.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWhat's the difference between T568A and T568B, and which do I use?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 24px;\"\u003eBoth are wiring standards for RJ45 connectors. T568B is the most common in commercial and home networks. T568A is used in some government and older installations. Use whichever matches the other end of your cable — just be consistent. The colour guide inside this connector supports both standards.\u003c\/p\u003e\n\u003c!-- FOOTER NOTE --\u003e\n\u003cp style=\"font-size: 12px; color: #999; border-top: 1px solid #e8e8e8; padding-top: 16px; margin: 0;\"\u003eNexus CAT6A Tool-less RJ45 Connector. Compliant with ISO\/IEC 11801 CAT6A Class EA and TIA-568-C.2. Sold in packs — see variant selector above for pack sizes.\u003c\/p\u003e","brand":"Nexus","offers":[{"title":"2 Pack","offer_id":46340751589573,"sku":null,"price":18.0,"currency_code":"AED","in_stock":true},{"title":"4 Pack","offer_id":46340751622341,"sku":null,"price":33.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/CAT6AUTPtoolless.png?v=1781182435"},{"product_id":"nexus-cat6a-coupler-rj45","title":"NEXUS CAT6A Coupler SFTP RJ45 10Gbps","description":"\u003c!-- BADGES \/ HIGHLIGHTS BAR --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px; margin-bottom: 20px;\"\u003e\n\u003cspan style=\"background: #EBF5FB; color: #1a6fa3; font-size: 12px; font-weight: 600; padding: 5px 12px; border-radius: 20px;\"\u003e⚡ 10Gbps Speed\u003c\/span\u003e \u003cspan style=\"background: #F4ECF7; color: #6c3483; font-size: 12px; font-weight: 600; padding: 5px 12px; border-radius: 20px;\"\u003e🛡️ SFTP Shielded\u003c\/span\u003e \u003cspan style=\"background: #EAF5E9; color: #276221; font-size: 12px; font-weight: 600; padding: 5px 12px; border-radius: 20px;\"\u003e🔩 Gold-Plated Contacts\u003c\/span\u003e \u003cspan style=\"background: #FEF9E7; color: #875a14; font-size: 12px; font-weight: 600; padding: 5px 12px; border-radius: 20px;\"\u003e🔌 Female to Female\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- INTRO PARAGRAPH --\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eStop replacing entire Ethernet runs just because one cable is too short. This \u003cstrong\u003eCAT6A SFTP RJ45 Coupler\u003c\/strong\u003e lets you join two cables together cleanly, keeping your network shielded, stable, and ready for speeds up to \u003cstrong\u003e10Gbps\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 24px;\"\u003eBuilt with a \u003cstrong\u003eshielded zinc-alloy housing\u003c\/strong\u003e and \u003cstrong\u003egold-plated contacts\u003c\/strong\u003e, this female-to-female keystone coupler snaps straight into standard wall plates and patch panels — no crimping, no re-terminating, no tools required. Just line up the two cable ends and you're back online.\u003c\/p\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- SPECS GRID --\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; letter-spacing: 0.06em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eSpecs at a glance\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666; width: 45%;\"\u003eCategory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCAT6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e10 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eShielding\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eSFTP (Foil + Braid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eRJ45 Female to Female, Keystone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eContacts\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eGold-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eShielded zinc-alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCat5e \/ Cat6 \/ Cat6A \/ Cat7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- WHY SFTP SHIELDING MATTERS SECTION --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 10px;\"\u003eWhy SFTP shielding matters\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eMost budget couplers use unshielded plastic housings that leave your connection exposed to \u003cstrong\u003eEMI\/RFI interference\u003c\/strong\u003e from power lines, fluorescent lighting, and nearby cable runs. Over longer distances or in noisy electrical environments, that interference shows up as dropped packets and inconsistent speeds.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 24px;\"\u003eThis coupler uses \u003cstrong\u003eSFTP construction\u003c\/strong\u003e — individually foil-wrapped conductors plus an outer braided shield, housed in a shielded zinc-alloy body. That keeps interference out at the exact point where two cables meet, so your join performs as reliably as the cable itself.\u003c\/p\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- KEY FEATURES LIST --\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; letter-spacing: 0.06em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eKey features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eSFTP double shielding\u003c\/strong\u003e — foil + braid construction rejects EMI and crosstalk at the join\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e10Gbps-ready\u003c\/strong\u003e — built to CAT6A spec for high-bandwidth tasks like streaming, gaming, and file transfers\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eFemale-to-female keystone design\u003c\/strong\u003e — works with Cat5e, Cat6, Cat6A, and Cat7 cabling\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eGold-plated contacts\u003c\/strong\u003e — resist corrosion and keep the connection stable over time\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eShielded zinc-alloy housing\u003c\/strong\u003e — stands up to daily handling in offices, racks, and home setups\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eTool-free install\u003c\/strong\u003e — snaps into standard wall plates and patch panels in seconds\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eNo re-crimping required\u003c\/strong\u003e — extend a run instantly instead of replacing the whole cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- IDEAL FOR SECTION --\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; letter-spacing: 0.06em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eIdeal for\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eExtending a run that came up just short of the wall plate or patch panel\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eOffice and commercial LAN installations\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eServer closets and structured cabling projects\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eHome network wall-wiring and patch panel repairs\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eGaming setups and 4K streaming installations needing a clean, shielded join\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- FAQ --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 16px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWill this coupler slow down my network?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eNo. As a shielded CAT6A-rated coupler, it's built to pass 10Gbps signals without adding meaningful loss, provided both cable runs and the coupler are properly seated.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eCan I use this with CAT6 or CAT7 cable, not just CAT6A?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eYes. The female-to-female RJ45 keystone design is compatible with Cat5e, Cat6, Cat6A, and Cat7 cabling. You'll operate at whichever category's speed is the lower of the two cables joined.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eDo I need any tools to install it?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eNo tools needed. It's a tool-free, snap-together design that drops into standard wall plates and patch panels, or can be used as a standalone inline joiner.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWhy choose a shielded (SFTP) coupler over an unshielded one?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 24px;\"\u003eShielding protects your signal at the exact point where two cables meet — often the weakest link for interference in a run. If any part of your cable path is shielded (S\/FTP, F\/UTP, etc.), using an unshielded coupler breaks that shielding continuity and can reintroduce EMI\/RFI issues.\u003c\/p\u003e\n\u003c!-- FOOTER NOTE --\u003e","brand":"Nexus","offers":[{"title":"6 Pack","offer_id":46514361041093,"sku":"NXCOUPLER6ARJ45-6Pack","price":42.0,"currency_code":"AED","in_stock":true},{"title":"4 Pack","offer_id":46514361073861,"sku":"NXCOUPLER6ARJ45-4Pack","price":28.0,"currency_code":"AED","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/6AKCMainPic.jpg?v=1783930315"},{"product_id":"nexus-cat8-sftp-rj45-tool-less-connector","title":"NEXUS CAT8 SFTP RJ45 Tool-less Connector 4-Pack","description":"\u003c!-- BADGES --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px; margin-bottom: 20px;\"\u003e\n\u003cspan style=\"background: #1A1A1A; color: #ffffff; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e⚡ 40 Gbps \/ 2000 MHz\u003c\/span\u003e \u003cspan style=\"background: #FEF0E6; color: #c0510f; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🏅 CAT8 Class II\u003c\/span\u003e \u003cspan style=\"background: #EAF5E9; color: #276221; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🛡️ Full Metal Shielded Body\u003c\/span\u003e \u003cspan style=\"background: #EBF5FB; color: #1a6fa3; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🔧 Tool-less Field Termination\u003c\/span\u003e \u003cspan style=\"background: #F4ECF7; color: #6c3483; font-size: 12px; font-weight: bold; padding: 5px 12px; border-radius: 20px;\"\u003e🧢 Dust Cap Included\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- INTRO --\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eBuilt for the demands of \u003cstrong\u003eCAT8 Class II infrastructure\u003c\/strong\u003e, the Nexus CAT8 Shielded RJ45 Connector delivers the full 40 Gbps \/ 2000 MHz performance your cable is rated for — without compromise at the termination point. The \u003cstrong\u003etool-less field termination\u003c\/strong\u003e design means no crimping tool required: insert, seat, and click — done in under a minute on-site. A full die-cast metal housing, gold-plated contacts, and a secure locking mechanism ensure the connector is never the weak link in your network.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 24px;\"\u003eDesigned specifically for \u003cstrong\u003e22 AWG and 23 AWG solid copper conductors\u003c\/strong\u003e — the heavy-gauge wire used in professional-grade CAT8 bulk cable including the Nexus 100m roll — this connector maintains the shielding continuity and impedance matching that CAT8's 2000 MHz bandwidth demands. Comes with a protective dust cap to keep contacts clean before installation.\u003c\/p\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- PERFORMANCE CALLOUT --\u003e\n\u003cdiv style=\"background: #0D1B3E; border-radius: 10px; padding: 22px 24px; margin-bottom: 24px;\"\u003e\n\u003cp style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.08em; text-transform: uppercase; color: #f97316; margin: 0 0 12px;\"\u003ePerformance at the termination point\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 120px; text-align: center; background: rgba(255,255,255,0.05); border-radius: 8px; padding: 14px 10px;\"\u003e\n\u003cp style=\"font-size: 28px; font-weight: 800; color: #fff; margin: 0 0 4px;\"\u003e40\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; color: #aaa; margin: 0;\"\u003eGbps max speed\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 120px; text-align: center; background: rgba(255,255,255,0.05); border-radius: 8px; padding: 14px 10px;\"\u003e\n\u003cp style=\"font-size: 28px; font-weight: 800; color: #fff; margin: 0 0 4px;\"\u003e2000\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; color: #aaa; margin: 0;\"\u003eMHz bandwidth\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 120px; text-align: center; background: rgba(255,255,255,0.05); border-radius: 8px; padding: 14px 10px;\"\u003e\n\u003cp style=\"font-size: 28px; font-weight: 800; color: #fff; margin: 0 0 4px;\"\u003e50µ\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; color: #aaa; margin: 0;\"\u003eGold-plated contacts\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 120px; text-align: center; background: rgba(255,255,255,0.05); border-radius: 8px; padding: 14px 10px;\"\u003e\n\u003cp style=\"font-size: 28px; font-weight: 800; color: #fff; margin: 0 0 4px;\"\u003e22–23\u003c\/p\u003e\n\u003cp style=\"font-size: 12px; color: #aaa; margin: 0;\"\u003eAWG conductor fit\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SPECS TABLE --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666; width: 45%;\"\u003eCategory\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCAT8 \/ Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eTermination Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: bold; color: #1a6fa3;\"\u003e\n\u003cstrong\u003eTool-less\u003c\/strong\u003e — no crimping tool required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e40 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e2000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eCompatible AWG\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e22 AWG \/ 23 AWG solid copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eContact Plating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e50µ gold-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eDie-cast full metal shielded body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eShielding Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003e360° metal housing — full EMI\/RFI shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eCable OD Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eSuitable for CAT8 S\/FTP bulk cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eWiring Standard\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eT568A \/ T568B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eDust Cap\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eBackwards Compatible\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eCAT5e \/ CAT6 \/ CAT6A \/ CAT7 \/ CAT8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 13px; color: #666;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; font-size: 14px; font-weight: 600; color: #222;\"\u003eNEXUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- WHY 22-23 AWG MATTERS --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 10px;\"\u003eWhy this connector is built for 22–23 AWG — and why that matters\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eMost RJ45 connectors on the market are designed around thinner 24–26 AWG conductors. At CAT8 frequencies — where the cable is carrying 2000 MHz of bandwidth — \u003cstrong\u003econductor gauge directly affects signal integrity\u003c\/strong\u003e. Thinner wire means higher resistance, more crosstalk between pairs, and greater signal degradation, all of which are amplified at 2000 MHz.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eThe Nexus CAT8 connector is engineered with \u003cstrong\u003ewider conductor channels and tighter IDC contact pressure\u003c\/strong\u003e matched to 22 AWG and 23 AWG solid copper — the gauge used in premium CAT8 bulk cable. This means:\u003c\/p\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 16px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eA gas-tight contact seal that eliminates micro-arcing and oxidation at the termination point\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eCorrect impedance matching (100Ω) maintained all the way through the connector\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eNo conductor deformation or splitting when inserting heavier-gauge wire\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eFull 40 Gbps throughput rather than falling back to a lower speed tier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 24px;\"\u003eIf you are running the \u003cstrong\u003eNexus CAT8 22AWG 100m roll\u003c\/strong\u003e, this is the connector that completes the end-to-end system — everything else is a mismatch.\u003c\/p\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- FULL METAL BODY --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 10px;\"\u003eFull metal shielded body — not plastic with a foil wrap\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.7; color: #333; margin-bottom: 16px;\"\u003eThe connector housing is \u003cstrong\u003edie-cast metal throughout\u003c\/strong\u003e — not a plastic body with a thin foil shield glued on. This matters for two reasons:\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 24px; font-size: 13px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 10px 14px; text-align: left; font-weight: bold; color: #444;\"\u003e\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; text-align: center; font-weight: bold; color: #c0510f;\"\u003eNexus Metal Body\u003c\/th\u003e\n\u003cth style=\"padding: 10px 14px; text-align: center; font-weight: bold; color: #666;\"\u003ePlastic + Foil Wrap\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eEMI shielding at 2000 MHz\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003e360° — full coverage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #c0510f;\"\u003ePartial — gaps at seams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eShield continuity to cable\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eDirect metal-to-braid contact\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #c0510f;\"\u003eFoil can detach over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eMechanical durability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eImpact-resistant die-cast\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #c0510f;\"\u003eCracks under port stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eGrounding path\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003eComplete — metal throughout\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #c0510f;\"\u003eInconsistent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 14px; color: #555;\"\u003eProfessional appearance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #276221; font-weight: 600;\"\u003ePremium metal finish\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 14px; text-align: center; color: #666;\"\u003eBudget look\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- KEY FEATURES --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eKey features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eTool-less field termination\u003c\/strong\u003e — no crimping tool needed; insert conductors, close the cap, done\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e40 Gbps \/ 2000 MHz\u003c\/strong\u003e — full CAT8 Class II rated performance\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e22–23 AWG matched design\u003c\/strong\u003e — built for heavy-gauge solid copper CAT8 cable, not generic thin-wire connectors\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eDie-cast full metal housing\u003c\/strong\u003e — 360° EMI\/RFI shielding with no gaps or foil compromises\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003e50µ gold-plated contacts\u003c\/strong\u003e — corrosion-resistant, gas-tight termination for long-term signal reliability\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eDust cap included\u003c\/strong\u003e — protects gold contacts from contamination before and during installation\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eSecure locking tab\u003c\/strong\u003e — positive click retention prevents accidental disconnection in patch panels and switches\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eT568A \/ T568B compatible\u003c\/strong\u003e — supports both wiring standards\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003eBackwards compatible\u003c\/strong\u003e — works with CAT5e through CAT8 infrastructure\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003e\n\u003cstrong\u003ePairs with Nexus CAT8 22AWG 100m roll\u003c\/strong\u003e — designed as a matched end-to-end system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- IDEAL FOR --\u003e\n\u003ch3 style=\"font-size: 13px; font-weight: bold; letter-spacing: 0.07em; text-transform: uppercase; color: #999; margin: 0 0 14px;\"\u003eIdeal for\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-bottom: 24px;\"\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eData centre and server room structured cabling at 25GBase-T \/ 40GBase-T speeds\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eField termination of CAT8 bulk cable runs — office, commercial, and industrial installs\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eHigh-density patch panel builds requiring a reliable shielded connector\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eNetwork upgrades where the full 40 Gbps headroom needs to be preserved end to end\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eGaming and AV-over-IP setups demanding maximum bandwidth with zero interference\u003c\/li\u003e\n\u003cli style=\"font-size: 14px; line-height: 1.8; color: #333; margin-bottom: 4px;\"\u003eAny install using heavy-gauge 22–23 AWG CAT8 cable that standard connectors can't seat correctly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- DIVIDER --\u003e\u003chr style=\"border: none; border-top: 1px solid #e8e8e8; margin: 24px 0;\"\u003e\u003c!-- FAQ --\u003e\n\u003ch3 style=\"font-size: 16px; font-weight: bold; color: #222; margin: 0 0 16px;\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWhy does AWG matter so much for a CAT8 connector?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eAt 2000 MHz, even small mismatches in the termination create signal reflections and crosstalk that can drop your link from 40 Gbps to 10 Gbps or lower. A connector designed for 24–26 AWG wire won't grip 22 AWG conductors with enough contact pressure — leaving a loose, high-resistance joint that fails under the electrical demands of CAT8. This connector is built around 22–23 AWG geometry from the ground up.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eIs this a tool-less connector? Do I need a crimping tool?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003e\u003cstrong\u003eNo crimping tool required.\u003c\/strong\u003e This is a \u003cstrong\u003etool-less field-termination connector\u003c\/strong\u003e — it uses a built-in IDC mechanism that seats and locks each conductor when you close the housing. Strip the outer jacket, fan the pairs into the colour-coded guide, insert, and click shut. That's it. No crimper, no punch-down tool, no specialist equipment needed on-site.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eIs this a field-termination connector or a factory-crimped connector?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eThis is a \u003cstrong\u003etool-less field-termination connector\u003c\/strong\u003e — designed to be terminated on-site onto bulk CAT8 cable without any tools. It is ideal for custom-length runs, in-wall or in-conduit installations, and any situation where pre-made patch cords are the wrong length or impractical to route.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWill it work with my existing CAT6A switches and routers?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 16px;\"\u003eYes. CAT8 is fully backwards compatible — the connector will work in any standard RJ45 port. The link will operate at the highest speed both ends support. Your infrastructure is future-proofed when you upgrade to 25G or 40G switches.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; font-weight: bold; color: #222; margin: 0 0 6px;\"\u003eWhat cable should I pair this connector with?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7; color: #333; margin: 0 0 24px;\"\u003eThis connector is specifically designed to match the Nexus CAT8 22AWG S\/FTP 100m bulk cable roll — both are engineered to the same CAT8 Class II specification. Using them together gives you a verified end-to-end system. It will also work with any third-party 22–23 AWG CAT8 S\/FTP bulk cable.\u003c\/p\u003e\n\u003c!-- CROSS-SELL --\u003e\n\u003cdiv style=\"background: #f7f7f7; border-left: 4px solid #F97316; border-radius: 0 8px 8px 0; padding: 16px 20px; margin-bottom: 24px;\"\u003e\n\u003cp style=\"font-size: 13px; font-weight: bold; color: #c0510f; margin: 0 0 6px; text-transform: uppercase; letter-spacing: 0.05em;\"\u003eComplete the system\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.6; color: #333; margin: 0;\"\u003ePair with the \u003cstrong\u003eNexus CAT8 22AWG S\/FTP 100m Roll\u003c\/strong\u003e for a fully matched, verified CAT8 end-to-end installation. Both products are engineered to the same Class II specification — cable and connector, built to work together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- FOOTER --\u003e\n\u003cp style=\"font-size: 12px; color: #999; border-top: 1px solid #e8e8e8; padding-top: 16px; margin: 0;\"\u003eNEXUS CAT8 Shielded RJ45 Field Connector. CAT8 Class II — 40 Gbps \/ 2000 MHz. Compatible with 22–23 AWG solid copper CAT8 S\/FTP bulk cable. Dust cap included. T568A\/T568B wiring standard.\u003c\/p\u003e","brand":"Nexus","offers":[{"title":"Default Title","offer_id":50609320132805,"sku":"NX-CAT8RJ45TL","price":62.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3212\/6661\/files\/CleanCAT.8connectorpair_720a14ca-9db9-4cee-a6d1-246f68e337bb.png?v=1790870551"}],"url":"https:\/\/shop.nexustrd.com\/collections\/connectors.oembed","provider":"Nexus","version":"1.0","type":"link"}